Electro Magnetic Compatibility (EMC)ce-test can perform virtually all tests required for the EMC-directive. We use the published and prescribed HARMONIC STANDARDS for house hold and light industrial equipment or for heavy industrial equipment. EMC-directive (89/336/EEC)Emission testing- Emission test E-field on Open Area Test Site according to EN 55022 en EN 55011.
- Emission test interference voltage according to EN 55022 en EN 55011.
- Emission test interference voltage on I/O and antenna connection.
- Emission test LF-magnetic field on 10 cm and 100 cm according to EN 55103-1.
- Emission test interference voltage on the mains connection according . to EN 55014 ("clicks").
- Emission test conducted interference voltage on I/O EN 55013.
- Emission test van harmonic current to the mains EN 61000-3-2.
- Emission test van mains voltage fluctuations according. to EN 61000-3-3.
- In-rush current according to EN 55103-1.
Immunity / Susceptibility testing- Radiated field according to EN 61000-4-3 from 80 MHz to 1000 MHz (3 and 10 V/m).
- RF- Current injection test according. to EN 61000-4-6 from 150 kHz to 80 MHz ( 3 en 10 Vrms over 150 Ohms)
- EFT / Burst test on mains and signal connections according to EN 61000-4-4.
- Surge impulses on mains and telecommunication connections according EN 61000-4-5.
- Electrostatic Discharges on the enclosure ESD test EN 61000-4-2.
- Magnetic field at low frequencies according to EN 55103-2.
- LF interference voltage in Common Mode acc. to EN 55103-2.
- Mains voltage variations and interruptions according to EN 61000-4-11.
Copyright (c) 2003 by ce-test. All right reserved news | services | features | technical | consults | testing | home Last modified
22-03-09 |